• Nem Talált Eredményt

W ” Correctionto “ High-ResolutionAdhesionKineticsofEGCG-ExposedTumorCellsonBiomimeticInterfaces:ComparativeMonitoringofCellViabilityUsingLabel-FreeBiosensorandClassicEnd-PointAssays

N/A
N/A
Protected

Academic year: 2022

Ossza meg "W ” Correctionto “ High-ResolutionAdhesionKineticsofEGCG-ExposedTumorCellsonBiomimeticInterfaces:ComparativeMonitoringofCellViabilityUsingLabel-FreeBiosensorandClassicEnd-PointAssays"

Copied!
1
0
0

Teljes szövegt

(1)

Correction to “ High-Resolution Adhesion Kinetics of EGCG-Exposed Tumor Cells on Biomimetic Interfaces: Comparative Monitoring of Cell Viability Using Label-Free Biosensor and Classic End-Point Assays ”

Beatrix Peter, Rita Ungai-Salanki, Bálint Szabó, Agoston G. Nagy, Inna Szekacs, Szilvia Bősze, and Robert Horvath*

ACS Omega 2018, 3 (4), 3882−3891. DOI: 10.1021/acsomega.7b01902

W e would like to correct a

gure shown in our original paper. On page 3385 of the original paper, in

Figure 3,

the units are mg/mL. The correct units are

μ

g/mL, and the revised

Figure 3

is plotted here. This erratum does not a

ect any of the results or conclusions described in the text. We apologize for the mistake.

Received: May 31, 2019 Published: June 17, 2019 Figure 3. Kinetic cell adhesion curves recorded by Epic BT. The

plotted lines represent the averaged values of the three parallel experiments. For obtaining these data, the cells were preincubated with solutions having different EGCG concentrations. After, these treated cells were pipetted into the biosensor wells and cell adhesion was monitored for 2 h. It is clearly seen that increasing the EGCG concentration decreases the sigmoidal character of the kinetic curves.

For the highest EGCG concentrations, the sigmoidal character is completely missing and adsorption-like curves are recorded.

Addition/Correction http://pubs.acs.org/journal/acsodf Cite This:ACS Omega2019, 4, 10474−10474

© 2019 American Chemical Society 10474 DOI:10.1021/acsomega.9b01597

ACS Omega2019, 4, 10474−10474 This is an open access article published under an ACS AuthorChoice License, which permits

copying and redistribution of the article or any adaptations for non-commercial purposes.

Downloaded via 193.224.44.72 on January 1, 2020 at 11:57:04 (UTC). See https://pubs.acs.org/sharingguidelines for options on how to legitimately share published articles.

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

The concentration-dependent influence of GPC on cell viability and the degree of oxidative stress were tested in 3-day-old primary rat cardiac myocyte cultures exposed to

Time-course of changes in cell size and water permeability in human induced plu- ripotent stem cells exposed to high glucose-induced hyperosmolar stress: iPS cells were detached

(i) to characterize the effect of decellularized porcine heart scaffold on cell adhesion of human cardiovascular cells potentially used in the recellularization process; and (ii)

The in vitro cell viability inhibition was tested on Detroit-562 human pharyngeal carcinoma cells that express GnRH-R in high levels, and the results showed that all conjugates

High resolution measurement characterizing the large number of cellular features is in the focus of recent cell biological research.. To achieve these goals single cell mass

The macrophage cytotoxicity assay with [ 3 H] or [ 14 C]thymidine-prelabeled tumor target cells avoids both problems: Spontaneous release of label (label re- leased by tumor

acnes strains differentially affected the proliferation and viability of HPV-KER cells, analyzed by following the cell number changes using a Bürker-chamber.. Increased cell number

Prognostic impact of reduced connexin43 expression and gap junction coupling of neoplastic stromal cells in giant cell tumor of bone.. Giant-cell tumor of