• Nem Talált Eredményt

24th International Symposium on Analytical and Environmental Problems

N/A
N/A
Protected

Academic year: 2022

Ossza meg "24th International Symposium on Analytical and Environmental Problems"

Copied!
2
0
0

Teljes szövegt

(1)

24th International Symposium on Analytical and Environmental Problems

280

DEVELOPMENT OF TARGETED LC-MS/MS METHOD FOR ANALYSIS OF DICLOFENAC AND ITS MAIN METABOLITES IN RAT LIVER PERFUSION SOLUTION OBTAINED BY NEW TYPE OF EX VIVO PERFUSION SYSTEM

Aya Dweny1, Tímea Körmöczi1, Orsolya Kovács2, Reza Samavati3, Róbert Gáspár2, Róbert Berkecz1

1Department of Medical Chemistry, University of Szeged, H-6720 Szeged, Dóm tér 8, Hungary

2Department of Pharmacology and Pharmacotherapy University of Szeged, H-6720 Szeged, Dóm tér 12, Hungary

3Department of Pharmacodynamics and Biopharmacy, University of Szeged, H-6720 Szeged, Eötvös utca 6, Hungary

e-mail: berkecz.robert@med.u-szeged.hu Abstract

Isolated perfused rat liver (IPRL) is used as ex vivo simulation for more accurate evaluation of pharmacokinetic parameters of target drugs, production of their metabolites and their excretion in the bile. Compared to in vivo systems, IPRL avoids the clearance of any other organ and permits the control over the factors that may affect the hepatic metabolism, for example, the flow rate of the perfusate, pH, pressure, and concentration of chemicals.

This simple experimental technique, unlike the cultured cells, keeps the intactness of the liver, in other words, cells other than hepatocytes, drug transporters' distribution, as well as enzymes, are still affecting the metabolism which gives a realistic picture [1-2].

The portal vein of the anesthetized rat was cannulated and the perfusion solution saturated with carbogen (95% O2 and 5% CO2) was pumped through it. The solution was directed through the transected abdominal vein to the waste. A cannula was inserted into the inferior vena cava through the right heart atrium through which the perfusate leaved the liver after the ligation of the abdominal vein. The isolated liver was then placed into the buffer vapour chamber of the recirculated perfusion system and the perfusate samples were collected during different time intervals.

The main goal of our work was the development of targeted reversed-phase LC-MS/MS analytical method for the analysis of diclofenac (DF) and its main metabolites namely diclofenac-O-acyl glucuronide (Glu-DF) and 4-hydroxydiclofenac (4´OH-DF) in the perfusion solution of rat liver. We are planning to use diclofenac as a reference compound in the future investigation of metabolism of designer drugs.

DF and its metabolites were extracted by the optimized liquid-liquid extraction procedure. LC separation was achieved by gradient elution of the mobile phase consisted of 0.1% formic acid in water and 0.1% of formic acid in acetonitrile on a Luna Phenyl-Hexyl column at 50˚ C with a run time of 10 minutes. The Agilent 1100 LC system was coupled to the triple quadrupole TSQ 7000 mass spectrometer. The appropriate transitions were monitored during the region of elution of each analyte. The linearity range of DF was between 100 ng/mL and 40 μg/mL. The related matrix effect, recovery and process efficiency were successfully evaluated.

Acknowledgements

This research was supported by the EU-funded Hungarian grant EFOP 3.6.1-16-2016-00008.

(2)

24th International Symposium on Analytical and Environmental Problems

281 References

[1] Pastor, Catherine M. "Isolated Perfused Rat Livers to Quantify the Pharmacokinetics and Concentrations of Gd-BOPTA." Contrast media & molecular imaging 2018 (2018).

[2] Bounakta, Sara, et al. "Predictions of bisphenol A hepatic clearance in the isolated perfused rat liver (IPRL): impact of albumin binding and of co-administration with naproxen." Xenobiotica 48.2 (2018): 135-147.

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

Moreover the effect of various additives was determined to get information about the relative contribution of the HO• and direct charge transfer based reactions to

parapsilopsis (ATCC 22019), using the Disk diffusion method for susceptibility testing, according to the Standard Rules for Antimicrobial Susceptibility Testing

Mercury intrusion porosimetry, in fact, measures the entrance towards a pore (Fig. All this means that for any pressure it can be determined which pore sizes have been invaded

Couplings with NiCl 2 as the catalyst required higher reaction temperatures and longer reaction times.. C-P couplings at C-2 or C-

BChl fluorescence (F) induction kinetics (inset) and lead-dependent changes of the maximum fluorescence (F max ) in intact cells of photosynthetic bacteria

Percentage of maize seed germination in the assay, has given different results: seeds that have been treated with the extract which had the concentration of 1 g/l 91%,

Amaranthus retroflexus, Celtis occidentalis, Portulaca oleracea and Setaria italic were determinated in very large numbers at each protected location, while a

There are several articles describing use of agro industrial residues for the production of cellulose such as wheat straw, wheat bran and rice straw as substrates for