Total site targeting with stream specific minimum temperature difference

Fodor, Zsófia ; Klemeš, Jiri Jaromir ; Varbanov, Peter ; Walmsley, Michael R.W. ; Atkins, Martin John ; Walmsley, Timothy G.

2012 august Abstract

The paper deals with an extension of Total Site Integration to Locally Integrated Energy Sectors producing more realistic utility and heat recovery targets. Process Heat Integration (based on Pinch Analysis) aims to minimise the amount of energy mostly used in industrial processes. It is still an open question how to solve the Total Site targeting problem when different values for the minimum allowed temperature differences (∆Tmin) are specified for each process on the site. A single uniform ∆Tmin for all processes integrated in a Total Site, as practiced to date, cannot be generally optimal. Such an assumption may be too simplifying and lead to inadequate results due to imprecise estimation of the overall Total Site heat recovery targets. The modified Total Site targeting procedure, proposed in this paper, allows obtaining more realistic heat recovery targets for Total Sites. It is illustrated with a case study for Locally Integrated Energy Sectors, also providing a comparison with the traditional targeting procedure and the advantages offered by the modified one.

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

This study presents four new contributions: (1) Total Site Sensitivity Table (TSST), a tool for exploring the effects of plant shutdown or production changes on

As a result of growing concerns about environmental problems over recent years, the design criteria for modern Total Sites and other systems need to consider,

This paper deals with aspects specific to the operation of diesel generator sets working both in isolated regime and as a back-up electric energy source for vital consumers who

The main energy components of the heat recovery system are the plate heat exchanger and the heat pump for higher and lower temperature range. The first stage of heat

The present investigation deals with (i) determination of total phenolic content, flavonoid content, anthocyanin content and evaluation of the antioxidant activity by several in

Dorfling, Goddard, Hattingh and Henning studied the minimum number of edges needed to be added to graphs of order n with minimum degree at least two to obtain two disjoint

47 Table 1 Multiple-site Jaccard dissimilarity (multiple-D J ; total beta diversity), species replacement (multiple-Repl PJ ) and richness difference (multiple-Rich PJ ) sensu