18 eredmény a kulcsszóra: 'maldi ms'
aureus reference strains in the Bruker MALDI Biotyper database; 83% of the isolates gave scores ≥2.300, so the species were safely identifi ed by mass spectrometry.. The MALDI-TOF
N/A
V. Kétdimenziós elektroforézis és MALDI-MS technika alkalmazása különböző hidrofób tulajdonságú albumin-globulin búzafehérjék azonosítására ...63.. Környezeti
N/A
Sample preparation method influences direct identification of anaerobic bacteria from positive blood culture bottles using MALDI-TOF MS.. Samo Jeverica, Elisabeth Nagy,
N/A
Although, the Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS) technique has become a promising alternative tool to
N/A
The optimized MALDI-TOF MS database was validated using 6309 anaerobic strains isolated from human clinical specimens.. The distribution of the genera is shown in
N/A
Furthermore, in order to assess the effect of added internal standard concentration on the calculated hepcidin concentration in urine sample, the MALDI-TOF MS peak intensity of hepcidin
N/A
All utilized 6 months' worth of anaerobic human clinical isolates encountered and identi fi ed using the MALDI-TOF MS Biotyper system (Bruker Daltonics, Bremen, Germany), which
N/A
16S rRNA gene sequencing was performed for a selection of the strains that gave discrepant results and for all those inconclusively identified by MALDI-TOF MS; 270 isolates (97.5%)
N/A
fragilis strains with known cfiA status, including NCTC 9343 (division I) and TAL3636 (division II), were measured by means of microflex LT MALDI-TOF MS and well-defined differences
N/A
The aim of this study was to test the accuracy of MALDI-TOF MS identi fi cation system using 400 Hungarian Bacteroides clinical isolates and to retest the strains with
N/A
Although this latter method is based upon much more correct boundary conditions than that of Kulka, one ·will find that the difference between values calculated from
N/A
We have previously shown the presence of PACAP in human serum, breast milk and follicular fluid using MALDI and MALDI TOF/TOF mass spectrometry analysis (Borzsei et al. 2011), so
N/A
─ teljesen véletlenszerű adathiányról (missing completely at random, röviden: MCAR) akkor beszélhetünk, amikor az adathiány nem függ az adatok értékétől
N/A
To our knowledge, this study is the first analysis of the GBS screening results and the antibiotic susceptibility pattern of GBS strains colonizing pregnant women in our region, and
N/A
LC-MS és LC-MS-MS módszerek elve, mérőrendszerek felépítése, analitikai információk értelmezése, alkalmazási
N/A
A két rendszer közti hasonlóságot erősítik például azok a tapasztalatok is, melyek szerint mindkét rendszerben vannak olyan területek, amelyeken a jogfejlesztést elsősorban a
N/A