• Nem Talált Eredményt

EFFECT OF PASTE SATURATION

N/A
N/A
Protected

Academic year: 2022

Ossza meg "EFFECT OF PASTE SATURATION"

Copied!
13
0
0

Teljes szövegt

(1)

EFFECT OF PASTE SATURATION ON CONCRETE STRENGTH AND DEFORMATION CHARACTERISTICS

By

Department of Building Materials, Technical University, Budapest Received June 13, 1977

1. Introduction

By the end of the past century, concretes have already been designed to have voids between coarse aggregate particles just filled out with mortar. These are termed paste saturated concretes. As early as 90 years ago, a method has been developed for determining cement dosage needed for paste saturation.

FERET, author of the first concrete design formula, took residual voids in the concrete into consideration. Also introduction of ideal grading curves and actual concrete design formulae strive to paste saturated concretes.

Hungarian - otherwise excellent - silica gravel aggregates are featured by an almost complete lack of below 0.25 mm size particles - especially after washing. The established practice of adding Portland cements grade 350 and 450 in dosages of 300 to 500 kg/cu.m tends to offset deficiencies in aggregate grading and concrete manufacture.

The described tests referred to the variation of concrete strength and deformation characteristics for varying paste contents, consistency being kept about constant.

2. Experiments

Applying Portland cement grade 450 from DCW* in dosages varying from 120 to 480 kg/cu.m, graded and washed aggregate approaching both limit curves (Fig. 1), fresh concrete composition and characteristics have been compiled in Table 1. Concrete consistency was nearly constant, the wlc ratio being altered only in tests 1/4 and 1/5.

The tests involved the follo, .. dng characteristics:

a) Concrete bending-tensile strength on 7 X 7 X 25 cm prisms with 21 cm spans, under third-point loading. Compressive strength was tested on portions of prisms broken in bending, with 50 sq. cm compressive surfaces.

b) Concrete cube strength on 20 cm cubes.

* Danube Cement Works 1*

(2)

4 BALAZS

--- Limiting curves to ME. 19-63

%

100~----+---i---~---~---t­

goHr----+---~----~---~----~r7~~~-,_--i 80Hr----~---~----r_---_=~,~~~r_--7_--~

~ 70~----~---_r---r_---~~~~~----~u=---T--~

1j Cl 60 r-Ti ---!

U I I

~

50,

r-+-1

----T----

.~ ~Oll ;

££ -,0 --I ---i-

20 11 - - - . - ' - : --:;-.~~.L-_ _ -+~~~."4~c_+-

_ _ _ ---:_-;--

10 /1- 11.

0.3

1/ __

L-- 2. - -

I

0.02 10

Fig. 1. Grading curves and limiting curves - - - Limiting curves according to ?tIE 19-63

c) Axial tensile strength on special 8-shaped tensile specimens 50 cm long, 12>< 12 cm mid-span cross section ah:o used for recording stress-strain diagrams by means of induction strain gauges of 40 mm basis length.

Symbol

1/1 1/2 1(3 1(4 1/5 1/6 1/7 1/8 1/9 1/10 1/11 Ill/I Ill/2 Ill/3 Ill/4 III/5 Ill/6

Table I

Compositions and consistencies of freshly mixed concretes

Real cement dosage, kg/ro.m

3-15 -Hi 475 344 350 260 155 119 332 480 151 477 346 155 418 256 129

Aggregate type

I

I I

I I I III III III III III III

Concrete cube : density, kg/en.m i

2430 2424 2386 2432 2462 2466 2334 2234 2436 2403 2375 2300 2300 2220 2330 2297 2178

wic

0.387 0.406 0.40 0.445 0.494 0.50 0.74·

0.80 0.43 0.39 0.75 0.47 0.50 1.05 0.49 0.6-1, 1.29

GlauyiIIe Compacting

Factor,CF

0.70-1 0.74 0.77 0.86 0.71 0.755 0.75 0.71 0.75 0.77 0.77 0.765 0.82 0.76 0.77 0.80

(3)

PASTE SATL'RATIO.V 5

3. Test results· and evaluation

a) The concrete hardening procedure is seen in Figs 2 and 3 to be con- sidered as linear vs. log. concrete age from 1 to 90 days. Concretes ·w1th cement dosages of 350 to 470 kg. cum are seen to exhibit a slight nonlinearity of bending-tensile strength, and those ,dth 470 kg/cu. m, of compressive strength.

b) Irrespective of age, compressive strength of 7 )< 7 )< 25 cm prisms decid- edly depended on the w/c ratio, differences increasing vvith age (Fig. 4).

Bending-tensile strength depended less on we ratio. Bending-tensile strength of concretes "lith w/e = 0,1. increased ",ith age, while the relative compressive strength was practically independent of age (Fig. 5).

c) Concrete compressive strength varied as a function of cement dosage according to a CllrYe exhibiting an optimum (Figs 6 and 7). Strength optima pertained at 1 day to a cement dosage of about 350 kg/cu.m, at 7 days to about 380 kg'cu.m, while at 90 days to about 420 kg/cu.m. Also bending- tensile strengths exhibited a marked optimum at 1 day for about 370 kg/cu.m of cement dosage. At 7 days this optimum was rather faint, while at 90 days the tested range exhibited no optimum at all.

Results confirm the earlier observation that increasing the cement dosage beyond a certain limit results in no strength increase any morc, especially as concerns the compressive strength.

!

7001 i !

I I Symbols, 'I

~

.I!1 + 1!2 ----- - , i ,

600 0 I 13 -._.--! ----+----i---;--f--:6""'::;;.-c--;7'9-

N E ,114 ··· .. ·1 1

i xI/5-- I

~ i ~ 116----· i

~ 500 v 117 -._.--+1' ---LI-J--~---__,:~;..L--'-7L--::7~--:;>,..:::..:'-

A 1/8--

£; I

f

400 !

Ui

.,

)

I I

I I

2 3 4 7 28 35 §O

Age (days) log l.

Fig. 2. Concrete compressive strength vs. age

(4)

6 BAL.4ZS

80h---~--~_+----+_---~~----~~

:1/1--1 + 112

---1

70 0 1/3 -._.-+--+--i---1---i7'-"---;""--:;;~;7.::w

• 114 ...•...• 1

E

60

.:::

~

x lIS--

A 1/6

---1

v 117-'-'--;--+-

.,1/8-1

~ 50~----~---+--+---~~7L~~~--<r_r---t_

~ QJ

tl

40I-I~---t-7F7'

l30

Cl') f.-I

if---~~--;~47L..---,.---~~--__t___t_-_::;;::7""'I-

I "'/

~ ! ;.--",/./

C i", /

&I 20 l' /

I .

r

. 1 3 4 7 28 35

Age (days) Fig. 3. Concrete bending-tensile strength vs. age

100 ~104¥-_!:.-__

+-____

-:::;!;;_==:"-t

90

Fig. 4. Strength vs. age of concretes made with different wle ratios Legend: - - - eompressive strength. - - - - bending-tensile strength

(5)

0 10

9 0 0

0 0 0 0 0 10

PASTE SATURATI01Y

1 ~"

1\\ :s:

~

\\ ~:~~

~

\ " -~ I""~I'~', '"

r., ... ~~" age

I \ aY2-

" ...

"'." I' ...

90

"

I I

.... -

...

- -

. ~

... ~ r-...

~ ... 28_ 7 7,28,90 1 -

0.4 05 0.6 0.7 0.8 w/c

Fig. 5. Relative strengths vs. w/c and age of concrete Legend: - - - compressive strength, - - - bending-tensile strength

800

roo

----i---+_--+_--+_----t1

j -

I t

700 qO~,_---+_--+_--+_--__t_--

600 0

,,5;-1---+---+----+---+-1-

E cJ .a.--...,I.a,?_ I

~

500 50-;+:

---+---7~----'Ir-~-""

...

""'l7

days

~ ~I

~ 400

!

400 500

Cement dosage, kg/m3 Fig. 6. 1 and 7-day concrete strengths vs. cement dosage Legend: • A compressive strength; LJ 6. bending-tensile strength

7

(6)

8 BALizs

800

1

80

_._.-<J

I ",.., .

.",0

/ . / . 0

700-70 /'

N E

I E

u /

.~.

~--_

u ...

.I /'"

:600-160~

/ / '

2400~!

en

~ I I

~

500,50!

I ;' M~

2350

1

g:

I

.@ I /

'(ij 400-

1

40./!l . I en

I !

I

e

0. 01 C I I g..2300~,

E I'O'~ ~ ,!

8

300T 30

~

J

I ~ ,

200120

!

822501:

I '

I

l°01Ll_0~_l_6 _~ __ --,-__ ~ __ ~_22_0--,O I

I

300 400 500

2450

100 200

Cement dosage, kg/m3

Legend : -

Fig. 7. 90-day concrete strength and density \'s. cement dosage

.-.0 hending-tensile strength. - - - III compressiye strength, - - - - 8, density

This tendency of strength development is in ,irtuaI contradiction to the expected increase of binding force ,vith increasing cement dosage. This contra- diction is virtual hecause of the importance of voids percentage in strength development. Nevertheless, concrete compactness can only be increased with cement dosage to a given limit, beyond that the voids content grows hence compactness decreases. The resulting strength optimum is somewhat shifted with respect to the compactness optimum.

d) Concrete cube strength (on 20 cm cubes) and cement dosage (Fig. 8) showed a relation similar to that in Fig. 7. Fig. 8 demonstrates a cement excess over about 300 kg/cu.m for the given aggregate to be useless from the aspect of compl'essive strength. Also here, concrete compactness had its maximum at about 250 kg/cu.m.

e) Also curves relating cement dosage and bending-tensile strength gave optima with aggregates both III and I, but the optimum was at a cement dosage of 400 to 500 kg/cu.m, referring to a higher paste demand.

f) From the aspect of saturation, a great importance is attributed to the total volume of cement and sand below 0.25 mm.

(7)

700

600T 2450

E

I M

U I E

~ 500

1

2400 ~

~ : £

e

400~ 2350 ~

~ I 0

fj) I

..8 I

3

3 00+2350

PASTE SATURATION

I I I

I

I I

! I

I I

! I

I

200

1

2250 I

I

lOOr 2200 I

I

I

t

8

100 200 300 400 500

Cement dosage, kg 1m3

9

Fig. 8. Concrete cube strength \"S. cement dosage. Legend: ~ compressive strellgth: 6. density

Cube strengths of concretes 1;1 through III have been plotted as a func- tion of concrete fines understood as above (Fig. 9). Strengths of concretes of identical consistencies are on two straight sections intersecting at a point con- sidered as optimum fines content. The interseetion point depends on the con- crete age. At 28 days the intersection corresponds to a dosage of about 400 kg/cu. m, and at 120 days to about 300 kg/cu. m. It is likely to be dependent also on the concrete consistency, namely strengths of concretes 15 and Ifl are outside the straight line. Tests 1;9, 1/10 and 1;11 are essentially the same as tests 1;4, L 3 and L7, leaving the tendency inaffected.

Bending-tensile and compressive strengths of prisms 7 X 7 X 25 cm made of concretes 11 through 1;11 have been plotted in Figs 10 and 11, respectively, as a function of the fines content in the concrete. Fig. 10 shows an optimum fines content for the bending-tensile strength to exist, decreasing from 390 kg/cu. m for 7-day concretes to 315 kg/cu.m for 90-day concretes. Slopes of both sections of the straight line connecting the strengths are seen to increase with concrete age. Compressive strengths exhibited a similar tendency (Figs 11, 12).

g) The curve for the relation between tensile strength and cement dosage of concrete gave an optimum (Fig. 13), just as did those bet"ween other strength types and cement dosages.

(8)

10

700r_---r--~----~--~----~

E

~600r_--_r----~--_+. ___ ~~--_+----+_

~

t500~---+----~--~~~-+----~----+­c:

1il ~

400 u

300r----r--~~--~

200f----+---i-

IOO~---+---'~---+----~--~---T-

lOO 200 300 400 500 600 Cement + fines below 0.25 mm, kg/m3 Fig. 9. Concrete cube strength vs. fines percentage

80r_---r--~---r--~-

10~--~--~----~--~----~--~-

100 200 300 400 500 600 Cement + fines below 0.25 mm, kg/m3 Fig. 10. Concrete bending-tensile strength vs. fines percentage

(9)

PASTE SATURATIOS

700~--~----~--~----~--~----~ i

I

I 100 200 300 400 500 600

Cement+ fines belCM' 0.25 mm, kg 1m3 Fig. 11. Concrete compressive strength vs. fines percentage

7001----+---

E

u

Cl. 600 60--+--+---1,..---+--~-. -r"-+--=--+-- .::::

..2 ~500 0--+--~--~-~,,-4,-~~~_r-

~

200 20-4----4----4---_4~~R---_4----+_

100 101--!---j!.---+----!..:w.r--4---_4---!-

100 200 300 400 500 600 700 Cement + fines below 0.2 mm, kg/m3

Fig. 12. Concrete bending-tensile and compressive strength vs. fines percentage Legend : - - compressive strength. - - - bending-tensile strength

11

(10)

12 BALAzs

3

§. E

i

30 i14OO-!+I---+-I-=--+~G5~+---+-"L---f--

i

'Oil

: 20 2350

~+l_

- , i I - - + - - 4 - - - + - - - , i - - - : . -

~

I I

I I

~7 \'

10 i1300 I

100 200 300 400 500 600

Cement dcsago, kg/m3

Fig. 13. Ten;:ile strength and density of llS-day concretes made with aggregate type I vs.

cement dosage

Legend: 1& - - - tensile strength, .:.. - . - - - density

h) With increasing cement uosage, the ultimate strain of concrete (Fig.

14) hence the extensibility of concrete increaseu about linearily. Thus, extensi- hility may he increased by higher cement dosages. On the other hand, exten- sihility of concrete LS showed a decrease beyond a given w,'c for identical cement dosage.

i) For cement dosages of 120 to 350 kg/cu. m the tensile strength was ahout proportional to the initial tensile modulus of elasticity (Fig. 15) but there over not. The tensile modulus of elasticity was understood as the asymp- tote of the initial tangent to the "virgin diagram".

j) In the cement dosages ranging from 350 to 500 kg/cu. m, the ratio of tensile-hending to compressive strength was ahout constant, and abruptly increased with decreasing cement content (Fig. 16). Hence to assume this ratio as constant seems only justified for paste-saturated and oversaturated concretes.

k) Also the ratio of compressive strengths found on 20-cm cubes and on 7 X 7 X 25 cm prisms is function of paste saturation rather than to be constant (Fig. 17).

(11)

PASTE SATVRATIOS

0.121---+I

1

--+----:--+---+-1--+-

I ./3"

I

J 010

I 12 I

~ I

!

008

rj----iI---:-t-""7"T-os-+j--+-I--f-

0006

1 ' I I

~

004

HAS- -t---+--Ir----+-j-+_

002

i i

I I

I i ! j

I i

I

100 200 300 400 500 600 Cement dosoge, kg / m 3

13

Fig. 14. "Ultimate elongation of llS-day concretes made with aggregate type I vs. cement dosage

40r---+---+---~

E

u 3 " 2

~30r---r--- r---~7T---

"

41

.!!!

.~ 20r---r----~~-+---T_----­

~

I

I I

'i

I

I

10r---+---+---~---

300 350 400 450

Eoh ; Mp /cm2

Fig. 15. Tensile strength VR. modulus of elasticity in tension (aggregate type I)

(12)

14

0.40

e

o

to.

c 30

ti ~

.~

~

E

8

.2 0.20

.!!l 'ifi .& c

I

.~ 'E QJ

CD

BALAzs

I

1

I ii

\

't 7~

I \

\ \

'''....-r-7 days

I

"~-t:.::; I

I I \

.12 3 1

0.10

I-L_.L---L

1 _\9_0 -LQQ_yS---' _ _ --L....1 _

+- I I i

100 200 300 400 500 600 Cement dosage, kg/m3

Fig. 16. Bending~tensile to compressive strength ratio (aggregate type I) 1.50

e

o ..c 0,

c ~ 100 ti .~ ..c

"'

::l

b

QJ .0 ::l

u 0.50

I

1

I I

I I

b .. I

I

I

I

I I

1\ I

I I

~ I

! I i : i

G

,,,- 6

I

I I !

I~I

i

I

i

~_I ~(I

1 1=

I

)2

I

I I

, I

I I

I I

I

100 200 300 400 500 600

Cement dosage, kg/m3

Fig. 17. Cube to modified cube strength (ASTM C 119-65T) ratio vs. cement dosage

(13)

PASTE SATURATION 15

Summary

The hardening process of I to 90-day concretes immersed in water has been investigated.

The concrete was made with standard aggregate and a cement dosage varying in wide ranges_

Compressive strength was found to depend on the w/c ratio at any age but the tensile strength was found to be little dependent. Higher wlc ratios reducing concrete density caused a strength loss. Given grading curves had an optimum cement dosage from the aspect of compressiYe strength, little manifest in respect to the tensile strength. The density optimum pertained to a somewhat lower cement dosage than did compressive strength optimum. Both unsaturation and oyersaturation increase the voids ratio in the concrete. An increased perccntage of fines.

demanded more cement for optimum strength and compactness. Optimum can be assessed from the density of freshly mixed concrete. Extensibility grew , .. ith cement dosage. The bend- ing-tensile to compressiye strength ratio increased for unsaturated concretes but for saturated and oyersaturated concretes it was nearly constant. _4.1so the cube to prism strength ratio de- pended on paste saturation.

Ass. Prof. Dr. Gyorgy BAL{ZS, head of dept., H-1521 Budapest

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

The e ff ects of steel fiber strength on the mechanical properties of steel fiber reinforced concretes, such as compressive strength, modulus of elasticity, splitting tensile

Using a statistical regression model, a polynomial function was determined for the variation of compressive strength from the outer region to the inner region of spun-cast concrete

The unuly,is of relationships between concrete strength und ultra,onic velocity in 20 cm cubes involved determination of Reimann's quantile functions eonstructed from

As regards porosity values, in the case of lower strength (C20/25) micro-fibre concretes are more porous than the macro-fibre specimens compared to the reference

It is known that the stress obtained by breaking a specimen which is subjected to uniaxial loading, shows the real tensile strength of concrete (Fig. 1), but the tensile strength

For the input parameters of the concrete model the following data from the laboratory tests was used: compressive strength, transverse tensile strength and the fracture energy of

Relative residual split-tensile strength of concrete (marking: wa- ter / cement ratio / maximum size of aggregate; dosage of PP-fibre V% and dosage of air-entraining admixture m c

The compressive strength of field-cured, standard-cured and core samples, and the rebound method calculated strength of structural concrete were obtained.. The results showed that