m/z = 120 M M (%) M+1 (%) M+2 (%)
C2H4N2O4 120,017107 100 3,15 0,84 C2H6N3O3 120,040916 100 3,52 0,65 C3H12N4O 120,101111 100 5,00 0,31 C4H12N2O2 120,089878 100 5,36 0,52 C6H6N3 120,056172 100 7,72 0,26
C9H12 120,093900 100 9,92 0,44
How much R is needed? R>30000
Requirement for small molecules: Accuracy < 10ppm (measured-calculated)/calculated*106
What is the accuracy of the measurement if M=120.091375 measured?
Alternative of elemental analysis: characterises the
individual components, not the sample in whole (Pro/Con)
HRMS: R>10000
Analyzers
Sector instruments
A sector field mass analyzer uses a static electric and/or
magnetic field to affect the path and/or velocity of the charged particles in some way. As shown above, sector instruments bend the trajectories of the ions as they pass through the mass analyzer, according to their mass-to-charge ratios, deflecting the more charged and faster-moving, lighter ions more. The analyzer can be used to select a narrow range of m/z or to scan through a range of m/z to catalog the ions present.
Time-of-flight
The time-of-flight (TOF) analyzer uses an electric field to accelerate the ions through the same potential, and then measures the time they take to reach the detector. If the
particles all have the same charge, their kinetic energies will be identical, and their velocities will depend only on their masses.
Ions with a lower mass will reach the detector first.
Quadrupole mass filter
Quadrupole mass analyzers use oscillating electrical fields to selectively stabilize or destabilize the paths of ions passing through a radio frequency (RF) quadrupole field created between 4 parallel rods. Only the ions in a certain range of mass/charge ratio are passed through the system at any time, but changes to the potentials on the rods allow a wide range of m/z values to be swept rapidly, either continuously or in a
succession of discrete hops.
Orbitrap
Orbitrap instruments are similar to Fourier transform ion cyclotron resonance mass spectrometers. Ions are
electrostatically trapped in an orbit around a central, spindle shaped electrode. The electrode confines the ions so that they both orbit around the central electrode and oscillate back and forth along the central electrode's long axis. This oscillation generates an image current in the detector plates which is recorded by the instrument. The frequencies of these image currents depend on the mass-to-charge ratios of the ions. Mass spectra are obtained by Fourier transformation of the recorded image currents.
Orbitraps have a high mass accuracy, high sensitivity and a good dynamic range.
Ion traps
The quadrupole ion trap works on the same physical principles as the quadrupole mass analyzer, but the ions are trapped and sequentially ejected. Ions are trapped in a mainly quadrupole RF field, in a space defined by a ring electrode (usually
connected to the main RF potential) between two endcap electrodes (typically connected to DC or auxiliary AC
potentials). The sample is ionized either internally (e.g. with an electron or laser beam), or externally, in which case the ions are often introduced through an aperture in an endcap
electrode.
MS n is possible
500000-1000000
– Extremely sensitive
– Broad range (40- 100kDa) – reproducible
– Whatever phase
– Easy combination with chromatography – Quantitation is possible
MS characteristics
100 spectrometers, no universal instrument
GC-MS
For high volatile molecules
SWOT analysis
Strength
- high sensitivity (10-15g) - fast (10 spektrum/s)
- efficient (simple sample preparation) - easily coupled with chromatography - quantitative and qualitative information
Weaknesses
- expensive (ca 100 000 Euro) - needs special knowhow
- interpretation is difficult
SWOT analysis
Opportunities
- verification (data base)
- macromolecules (proteomics) - broad field application
Threats
- not every compound is detectable
- sensitivity is heavily dependent on compound
- precaution is needed when used together with chromatography
Nitrogen rule
If M is even, then number of N is even (CHNOSF molecules).
Fragmentation rules
chain branching: possible positions for cleavage
stable molecules tends to leave (CH2=CH2, CHCH, CO, CO2, HCl, H2O, N2, NO2 etc)
formation of stable cations (allylic, formyl, acetyl, tropilium, etc)
General rules
Fragmentation is unique to every compound Depends heavily on instrument/settings
A structure can be verified or excluded based on the fragmentation pattern, but not elucidated (there are exceptions)
„The spectrum is in accordance with the suggested structure”.
https://chem.libretexts.org/Bookshelves/Analytical_Chemistry/Supplemental_Modules_(Analytical_Chemistry)/Instrument al_Analysis/Mass_Spectrometry/Mass_Spec/Mass_Spectrometry_-_Fragmentation_Patterns
(m/z = 44) (m/z = 72)
(m/z = 58)
H3C N H
CH2 +
+ H3C N H3C
CH2
ónium-reakció McLafferty-
átrendeződés ónium-reakció
(m/z = 86) (m/z = 114)
+ H3C N H3C
H
-hasadás
-hasadás
CH3 N
H3C CH3
CH2 +N +
H
H3C
H3C CH3
CH3 N H3C
CH3 +
+
(m/z = 129) CH3 N
H3C CH3
CH3
ku69941_ra-61-1-f_d_qe920 09/23/19 14:15:24 Hazai L./ Pallag E.
RT:0.00 - 9.50
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5
Time (min) 0
10 20 30 40 50 60 70 80 90 100
Relative Abundance
6.09 6.11 6.15
5.92 5.96 5.85
5.81 6.21
5.73 6.31
5.66 5.59 6.33 5.48
6.41
5.36 6.45
5.25
6.50 5.15
5.07 4.98 4.87 6.57
6.65
4.76 6.76 7.73 7.95 8.10 8.22 8.36 8.60 8.73 9.41
4.43 4.56 3.34 4.17
3.10 3.90
2.95 2.69 2.01 2.31 1.82
0.01 0.29 0.56 1.05 1.33 1.59
NL:
3.17E8 TIC MS ku69941_ra -61-1- f_d_qe920
ku69941_ra-61-1-f_d_qe920 #2214-2848 RT:5.22-6.38 AV:635 NL:2.06E7 T:FTMS + c EI Full ms [33.0000-600.0000]
40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440
m/z 0
10 20 30 40 50 60 70 80 90 100
Relative Abundance
349.07055 C20H13O6
14.5 RDBE -0.32713 ppm
310.04712 C17H10O6
13.0 RDBE -0.22318 ppm 296.17564
377.06544 C21H13O7
15.5 RDBE -0.37472 ppm 175.03897
C10H7O3
7.5 RDBE -0.03077 ppm
416.08900 C24H16O7
17.0 RDBE -0.12134 ppm 358.13160
254.05736 C15H10O4
11.0 RDBE 0.01477 ppm 226.06253
C14H10O3
10.0 RDBE 0.36945 ppm 121.02841
C7H5O2
5.5 RDBE 0.05268 ppm 91.05427
C7H7
4.5 RDBE 0.44831 ppm
39.02278 328.08470
http://chemistry.syr.edu/totah/che575/support/3a1/3-3.MS.pdf