SOME PROBLEMS OF PRODUCING AERATED CEMENT OR CONCRETE

Zs. R. FARAGO Department of Building :Materials Technical University, H-1521 Budapest

Received March 30. 1989 Presented by Prof. Dr. Gy. Balazs

Abstract

A complex testing of aerated cements and aerated concrete and some of the test results are discussed in this article.

Properties of foam cements were tested on several cements. Tests showed that strength depends on the quality and quantity of components and mainly on the size of pores which is the result of the production technology.

A continuous test program shows that the development of aerated concreteicement sa- tisfies the requirements of current constructions.

I. Introdnction

There is a trend in Hungary to use precast and site cast heat insulator concrete to introduce energy conserving building technologies. The most common of all heat insulator concretes are the aerated cements and aerated concretes ,vith a ,vide range of parameters. Aerated concrete has been produced in Western Europe and in some of the developing countries for more than a decade. The detailed recipe of aerated concrete and the full description of production technology is usually not available or not fully applicable to the Hungarian binding materials and aggregates. The technology of aerated con- crete is a very new Hungarian production and started only a few years ago.

Several companies, including the Department of Building :Materials, have tried to develop and introduce production technologies.

The research has not yet come to an end but part of the results are worth publishing. Research work at this stage is focusing on finding tendencies and not on evaluating numerical properties.

2. IViaterials

The follo\\ing cements from different factories with different ages were used: Beremend 350 F APC-IO, Beremend 450 PC, Belapatfalva 450 PC and Vac 450 RPC. FOA:NIIN "C" was the aerating agent. Table 1 summarizes the mineral composition and physical properties of the cements. The Beremend 350 FAPC-IO was a Beremend 450 PC cement plus 10% acidic fly ash added.

(2)

72

Components m

AM CaO total

C.S CaS C;A

C4AF }fgO S03 CaO (free)

~,~

oss on burning

I ~

Strength MP'a Flexural

1 days 7 days 28 days Compressiye

1 days 7 da::"s 28 days

Specific surface m2/kg (Blaine test)

ZS. REDEY·FARAGO

Table 1 The Properties of Cements

Cements

Berem('nru Belnpatfalvai Yaci

450 p 450 pc 450 Rpc

1.73 1.57 1.67

60.61 62.36 60.77

49.28 55.20 47.82

21.60 18.81 22.28

9.33 7.03 9.67

9.79 10.95 10.83

2.48 2.01 2.28

3.23 1.94 2.40

0.49 0.32 1.50

1.15 1.32 1.62

3.72 4.26 3.88

6.80 8.61 8.02

7.90 8.91 8.17

16.4 15.8 17.1

35.2 36.7 35.8

45.0 4·7.7 45.3

311 ,to7 356

The properties of the hydralized protein based FOAMIN "C" are:

dark brown colour, easy foam generating,

density at 20°C: 1141 kg/m3 ,

pH: 7.0,

viscosity (OSTWALD) at 20°C: 7.5 X 10-3 Pas, solid content (dried at 100°C): 31.0 m%,

viscosity (DIN-04 mm) at 20°C: 11.88s,

Beremendi 350 ppc 10

3.06 3.80 4·.20

11.6 25.1 35.8

255

sulphate and chloride content: detected in a small quantity.

i$. Foams

During the reseach project mainly mechanically produced, airblown foams were tested. FOAMIN "COO (2.5 m%), water and cement were foamed in a Turbofoam. The body density of the foams varied between 38-108 kg/mB in

(3)

PRODUCIlVG AERATED CEM:ENT OR CONCRETE 73 relation to the air pressure used. The foams around 75 kg/m3 body density were found to be the most appropriate for further tests because these foams had the least slump. Mechanical foam beating resulted in heavier foams than airblo'wn ones and smaller pore sizes in the foams.

4. The effects of foaming agent on the properties of concrete The setting times of the cements were determined according to MSZ 523 (Hungarian Standards). The effects of the foaming agent on setting time was tested of the standard cement paste mixture plus 1 m

%

foaming agent (by cement mass). There was a cement which became softer when the foaming agent was added, thus the standard cement mixture could have been produeed 'with less water.

As Table 2 indicates, tests show that the foaming agent had a great in- fluence on the setting time of concrete. Although the exact relationship be- t"ween the added agent and setting time was not discovered, it was found that the amount of setting water was not proportional to the resulting retarding effect. This retarding effect meant that the foaming agent increased the con- sistency of the cement paste.

Hardening of the cement was tested according to MSZ 523 (Hungarian Standards on strength test of binders) and mortar was mixed using ISO mixer. The initial strength of the binders influenced the consumption of foam cements and foam concretes and thus the strength at 20 hours was always

Table 2

The effect of FOAJIIN "C" on setting time

Setting time

start end

hour ruin 01 "0 hour min C! 10

Beremendi standard

450 pc cementpaste 2 35 100 5 20 100

paste

+

foaming agent 6 20 217 9 0 169

Beremendi standard

350 ppc-l0 cementpaste 6 ?-~;) 100 5 0 100

paste

+

foaming agent 6 50 200 10 0 200

Belapatfalvai standard

450 pc cementpaste 3 20 100 4 30 100

paste

+

foaming agent 5 0 150 5 50 130

Vaci standard

450 Rpc cementpaste 2 10 100 3 15 100

paste

+

foaming agent 3 45 173 4 40 144

(4)

74 ZS. REDEY-FARAGO

measured. During the evaluation the effects of the foaming agent were com- pared to those samples which were made without the agent. It is stated, ac- cording to Table 3, that adding 1

%

foaming agent results in

20-34% lighter body density,

o

-67% lower flexure strength and 23-77% lower compressive strength.

The largest decrease of the tested properties was observed on the Beremend 350 FAPC - 10 mixture.

Cement

Beremendi 450 pc

Beremel1di 350 pp-10

Belapatfalvai 450 pc

Vaci 450 Rpe

Table 3

Strength of 20 hours aerated mortars

.\ vera::;:c body

Cmnponents. Storing deiisity . flcxural

kg/m" 0 =-'/nlm!:

mortar free air 2133 100 1.42

mortar -7-foaming

agent free air 1709 80 0.89

mort a; + foaming

agent steam 1583 74· 1A8

mortar free air 2164 100 0.98

mortar +foaming

agent free air 1504 70 0.32 mortar + foaming

agent steam 1437 66 0.74

mortar free air 2150 100 1.79

mortar -'- foaming

agent free air 1663 77 1.15

mortar free air 2117 100 1.39

mortar foaIning

agent free air 1628 77 0.56

mortar";" foaming

agent steam 1484- 70 0.94

5. The properties of aerated cements

Average strength tensile compressive

0/ 0 Njmm' 0' ,0

100 4.49 100 63 2.12 47 10-1 1.46 77

100 3A7 100 33 0.80 23 76 1.38 40

100 4.75 100 64 2.18 46 100 4.59 100 40 1.69 36 68 2.10 48

The strength properties of airhlown cement pastes with 1.5-3.0 mm pores diameter are shown in Figures 1-3 and the strength properties of the airblown, mechanically heaten micropore foam cements are sho'wn in relation to the hody density on Figures 4 and 5. For comparison the strength properties of NEOPOR foam cements are available in the bibliography. On Figure 6 the thermal conductivity of aerated cements, measured 'with the Bock device at

(5)

<>----<>

0...---0

&-.--1)

x--x

X---1(

iOOO

I~

E

~8C() ,t;r---t:.

T

200

PRODUCING AERATED CEMENT OR CONCRETE

water cement

057169 0.6125 0.6410 0.6124 0.6751 0.5604 0.5012 0.5100 0.4466 05465

cement

~ c 0.389 0.494 0.567 0.494 0.68i 0.386 0.49i 0.257 0.092 0.350

o -'

---~-

! 0 ; 2 '.4 1.6 1.8 2.0 22 2.4 2.6

Air pressure. bar

Fig. 1. Changing the body density of airblown fresh aerated cement with air pressure

0.. 0

::E x

.c 0.4

en

c: x scheme

::: 0.3

Ul

~ Ui E

c: 0.2

D

E--"<-

.Cl:! r--

0

1 t-'

CJl -v-

c: 707mm

U 0.1 -+--.~

c: OJ CD

0

75

Fig. 2. The flexure strength of airblown, dry VAC 450 RPC aerated cement related to the body (sample ages were 28 days or older)

(6)

76 ZS. REDEY·FARAG(J

2.0 Loading scheme

F

=

E

0 1.6 _______ x.

0

E ...

Cl. 8.

2: x

,-""

.c ~l00mm

1.2 -r----+-

01 100 mm

c w --i:'--T-

X U1 0.8

w

.D x

::J x x

U

O.L "'-x>: J< -x .

XX X X X

X

0 200 400 600 800 1000 Body density.

Fig. 3. The compressive strength of airblown, dry VAC 450 RPC aerated concrete related to the body density (more than 28 days)

Aqe at 'est· l

Load ir.g scheme

"'" 2 days old 6.0

Cl. 0 2: 5D :S

01

t= E

g I' E.o;,.

I I 0 0,

~-'<-

Do Z

x 7 days old, stored under 100mm " ,40

~ @ water

~ c 4.0

U1

i60mm

""

c'.---:-

i

1

e'

~ U1 3D

~ c

I

e 28 days old, stored under

"'" water

!e 1{'

I 01 c '6 2.0 c w ID

1.0

i x @ 7 days old, from other

<!{~ @

e + sources

.~ x @<!

~ 1++

+++ + I

0 200 400 600 800 1000 1200 1400 Body density, kg/m3 Fig. 4. Flexure strength of airblown and beated FOAMIN "C" aerated cements

25 QC temperature, is compared to the thermal conductivity of NEOPOR foam concrete.

The summarized test results indicate that the strength of aerated ce- ment and concrete depends on the production technology. Airblown foams are

(7)

o

PRODUCliVC AERATED CEMENT OR CO:VCRETE

Loading scheme

200 400 600 800

Age at test:

+ 2 days old

@ x 7 days old, stored under water

Cl 28 days old, stored under ,(,ater

@'7 days old, from other sources

1000 1200 Body density, kglm3

Fig. 5. Compressive strength of airblown and beaten FOAlIHN "C" aerated cements

Foamcement made by using

x lnblown air + mixing 10

0.8 Chamber temperature: + 25°C

o

Inblown air

~ 0.6 Spec imen: 250 x 250 x 65 mm :~ u

::J 0.4 j----,,----,----;---.---~---,-

§

u

o

02 +---+----~---~~_,_----~----­

E C;

.J:.

r-

@ Thermal conductivity of the foam cone rete (NEOPOR) from DIN 52612

o

200 400 600 800 1000 1200 1400 Body density, kg 1m3

77

Fig. 6. The thermal conductivity of FOAMIN "C" aerated cements related to the body density (more than 28 days)

lighter with larger pores and have lower strength compared to mechanically beaten foams. The thermal conductivity of the foams is less sensitive on the production technology than on all the other properties of foam cements.

Zsuzsa FARAGO H-1521, Budapest

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

The results (Fig. 5) show that the compressive strength of the samples is decreasing with the increase of the size (edge length/diameter or volume), regardless of the shape or

The expected conditions of the concrete tested in struc- tures correspond with normal concrete use; that is, substan- tially lower internal stress values are taken into account

The results of the sensitivity analysis indicate that the response of the structure is very sensitive to the concrete and steel parameters for larger values of the shear

Using a statistical regression model, a polynomial function was determined for the variation of compressive strength from the outer region to the inner region of spun-cast concrete

Since long, there have been attempts to develop a formula, for the use of concrete designers, helping to predict the concrete strength, the heat generation during

The unuly,is of relationships between concrete strength und ultra,onic velocity in 20 cm cubes involved determination of Reimann's quantile functions eonstructed from

Full scale tests show that the aerated concrete material, regarded as homogeneous, has a different thermal conductivity through the wall cross section.. The relationship

If the dimensions of the structure (walls, piers, slabs, etc.) make it possible, a special poor concrete is cast as core concrete 'with higher d max and with a cement