• Nem Talált Eredményt

[1-6].

N/A
N/A
Protected

Academic year: 2022

Ossza meg "[1-6]."

Copied!
5
0
0

Teljes szövegt

(1)

OPTICAL SURFACE ROUGHNESS MEASUREMENT OF MACHINED SURF ACES**

'I. PECZELI, P. RICHTER, *0. BERKES

Department of Atomic Physics and *Department of Machining Engineering Technical University H-1521, Budapest

Received June 30, 1989

Abstract

An optical method is described that makes measurement of surface roughness of machined parts in a wide roughness range possible. The apparatus based on a diode laser can be mounted on CNC machining centers as diagnostic tool for checking tool wear. Principles of operation and calibration results are described.

Introduction

Control of uniformity of surface roughness of machined parts is of major importance for automated mass production. Furnishing highly productive machining centers with diagnostic measurements can diminish rejects. Change of surface roughness in serial production is mainly due to tool wear. Therefore an early warning of surface roughness change is highly desirable.

A relatively simple optical method to control uniformity of surface roughness in a wide roughness range, and a measuring head that can be mounted on CNC machining centers was developed and will be described.

Calibration results and some hints on its application will be given.

Principle of operation several optical methods are known for surface roughness measurement [1-6]. However, most of them suffer from the limitation that they measure roughness within a relatively small range, or they are very sophisticated and expensive.

In the present optical setup shown ill Fig. 1 alternative processing of the emerging signals from the same measuring head make significant extension of the measurement range possible.

The surface to be tested is moving perpendicularly to the optical axis in the focal region of the focusing objective and the back scattered light is sensed by the detectors. Empirically it was found that both in the case of smooth and of rougher surfaces the ratio of the average AC component to the DC component of the signal of detector D2 , which is normalised by the DC component of the signal of detector D 1 shows good correlation with Ra

** Dedicated to Pr of. J. Giber on the occasion of his 60th birthday.

(2)

of the surface. The lens Lz reimages the illuminated part of the surface on aperture A. With the surface moving forward and away focus the image size changes drastically just as the signal of detector Dz which is normalized by the signal of

D

l ' S =

(D x~:~:'c

1 ) . The distance of the optical head from the measured surface is kept constant by a polished slide, which allows moving

DL

CL

ss FO

s--.¥.---

Fig. 1. Optical setup of the measuring head DL diode laser, CL-collimating lens, BS-beam splitter, FO-focusing objective, S-surface to be tested, D1 : Drdetectors, L1 : Lz-Ienses, A limiting

aperture

Fig. 2. Photo of the equipment

(3)

ROUGHNESS MEASUREMENT OF MACHINED SURFACES 221

the head up and down to keep the focal plane of the head at the average surface of machined part. The measuring equipment is shown in the photo of Fig. 2.

Experimental results

Test measurements were carried out on a flat etalon senes. The measurements were carried out on each sample nine times in the surface roughness range of Ra = 0.05-10 !1m. The RMS values were below 2.10-2 at every measurement. Scanning velocity was 1 mm , and the scanned length

s was 10 mm.

;; 20

Cl

NI,u

u 0

'~1<~15

10

5

0.1 0.2 0.4 0.8 1.6 3.2 6.4 12.8

A-C,

Fig. 3. _ : as function of Ra values D CzD Cl

Figure 3 shows the measured values

~~~C:.c

as a function of Ra.

D 2D 1

By means of the equipment lathe-turned internal surface of steel pipe was tested at different powerfeeds and two depth of cuts.

(4)

The technological parameters were a) at rough cutting

depth of cut: a = 2 mm

power-feed: s=0.2; 0.25; 0.3; 0.35; 0 . 4 -mm turn r.p.m.: 650-. 1

mm

A·C2

/

E 8

D·C2 D•C1

'to

:a..

- i

"

0:

i ,

/

1" "

6

i

I - -

I

Ra

i ,

I I

4 I

I

f ' ,

"

,

'"

i'

2

16

14 13 12 11 10 9

0.2 0.3 0.4 8

Feed, mm/turn

- .

.

U <

.

Fig. 4a. Rough cutting a = 2 mm

E 1.1 :J..

0:0 1.0 0.9 0.8 0.7

u

0

u N

0

N' U

7 ,I,.) ~

< , I,.) 6 0

Feed, mm/turn Fig. 4b. Sleeking a = 0.2 mm

(5)

ROUGHNESS MEASUREMENT OF MACHINED SURFACES

b) at sleeking

dept of cut: a = 0.2 mm

Power-feed: s=0.018; 0.025; 0.05; 0.1; 0.15-mm turn

r.p.m.: 650-. 1 mm

223

The measured values of x

~~

C:.

c

are shown in Fig. 4a, b, as function D 2D 1

of power-feed. Ra value of the turned pipe, measured by a stylus instrument are shown as well.

Conclusion

This "semi-contact" optical method is suitable for examination of surface roughness of machined parts on CNC machining centers. By pre-setting upper and lower values of the processing signal indication of rejects is possible. The measuring head can be easily mounted onto the tool holder. In this case for practical purposes an infrared transmitter can forward the data from the measuring head for further processing.

References

1. FUJIJ, H. and ASAKURA, T. (1985): Optical Commun. 11, p. 35

2. FERCHER, A. F., Hu, H. Z. and VRY, U. (1985): Applied Optics 24, p. 2181 3. BRODMANN, R. (1986): Precision Engineering p. 221

4. LORINCZ, E., RICHTER, P. and ENGARD, F. (1986): Applied Optics 25, p. 2778

5. PECZELI, 1., ENGARD, F., RICHTER, P. (1986): Finommechanika-Mikrotechnika 10-11, p. 323 6. KIMIYUKl Mitsui, MAKOTO Sakai and YOSHITSUGU Kizuka (1988): Optical Engineering 27,

p.498

I. PEcZELl }

P. RICHTER H-1521, Budapest

Hivatkozások

KAPCSOLÓDÓ DOKUMENTUMOK

Consequently the difference of the surface roughness parameters is caused by the different working method of the laser triangular and the stylus type measuring systems.. It means

Near-field intensity distributions were determined by FDTD calculations for micrometer-sized gold coated inverse pyramids with flat and rough surface, and with

It has been found that the analysis of most of the studies eval- uating machining performance in terms of the tool life, surface roughness, cutting forces and chip morphology

The measured data shows, that the increasing feed of turning or the increasing depth of cut of the milling increase the surface roughness, while the increasing

By setting the optimum cut distribution, the life of the grinding wheel and the surface roughness can indirectly be kept at the optimum value.. The production of

Nowadays, this means that it can be used for performing simple manual calculations and complicated scientific computations, for on-line control of measuring instruments

line can be transformed into a line consisting of a central conductor b~tween two infinite parallel planes. If the resonator is made of finite planes instead

Hence the contact area when the approach exceeds the maximum height of asperities in the longitudinal direction, is equivalent to the product of contaet length in